Split-type Electro-hydraulic Actuator
A Reliable Solution for High-Temperature Environments
Many customers face the same challenge: ambient temperatures at the installation site are too high for a conventional actuator. The Split-type Electro-hydraulic Actuator is designed for applications where heat management is a critical concern. The cylinder is mounted directly on the gate, while the hydraulic power unit can be installed up to 10 meters away in a cooler, shaded area. The two components are connected by high-pressure oil pipes, keeping heat generated by the power unit away from the cylinder. Since the cylinder contains no motor or oil tank, heat-generating components are kept away from the working end.
The standard oil pipe length is 2 m, with custom lengths available up to 10 m. Pipe bore options include 10 mm and 16 mm, with a minimum pressure rating of 16 MPa. These options help control pressure loss in extended hydraulic lines. Thrust ranges from 10 kN to 5,000 kN, covering the highest thrust range in our actuator lineup. The separate oil tank is available in capacities from 10 L to 200 L, allowing greater flexibility in tank sizing without being restricted by the cylinder's mounting space. The larger tank also supports heat dissipation and S1 continuous duty, enabling 24-hour operation under suitable operating conditions. An air-cooled or water-cooled system can be selected according to the ambient temperature and site requirements. The product complies with JB/T 12705-2016.

Full-System Testing Before Shipment
Our factory follows a dedicated assembly and testing process for every Split-type Electro-hydraulic Actuator. The cylinder and hydraulic power unit are assembled and tested separately in the workshop. After the valve block passes its bench test, we connect the cylinder and power unit using a 2 m test pipe and perform a complete system operation test. Once the system passes inspection, the components are disconnected and packed for shipment.
Upon delivery, customers only need to connect the oil pipes and power supply, then bleed air from the cylinder and hydraulic lines before operation. On-site pressure adjustment is not required under the standard tested configuration.
Two years ago, we supplied eight split-type actuators to a power plant in North China for operating ash gates at the bottom of its boilers. The ambient temperature at the site remains above 65°C throughout the year, and the floor is exposed to heavy ash accumulation. The hydraulic power units were installed in a separate room approximately 15 m away from the actuators. According to the project history, the units operated for three years without shutdowns caused by high oil temperature. Before the upgrade, the plant used integrated actuators and replaced their seals twice a year.

Considerations for Oil Pipe Length
Each additional meter of oil pipe can result in approximately 2% to 3% pressure loss, depending on the operating conditions and pipe configuration. For pipe lengths exceeding 6 m, we install an accumulator inside the hydraulic power unit to help compensate for pressure fluctuations and maintain stable actuator performance. The actual thrust and operating speed depend on the final hydraulic circuit design and operating conditions.
For a port project, we supplied a split-type actuator system with a 9.5 m oil pipe. The measured thrust loss at the cylinder end remained within 5%.
Specifications
|
Parameter |
Specification |
|
Cylinder and power unit |
Fully separated components connected by high-pressure oil pipes |
|
Standard pipe length |
2 m; custom lengths available up to 10 m |
|
Pipe bore |
10 mm / 16 mm |
|
Minimum pipe pressure rating |
16 MPa |
|
Oil tank capacity |
10 L to 200 L |
|
Thrust range |
10 kN to 5,000 kN |
|
Duty cycle |
S1 continuous duty (24-hour operation under suitable conditions) |
|
Cooling options |
Air-cooled or water-cooled system |
|
Product standard |
JB/T 12705-2016 |
|
Typical industries |
Power plants, steel mills, ports, and high-temperature mining applications |
FAQ
Q: Do I need to adjust the pressure after receiving the unit?
A: No. We test the cylinder and hydraulic power unit together as a complete system before shipment. After installation, connect the oil pipes and power supply, then bleed the air from the hydraulic lines and cylinder before operation.
Q: What if my oil pipe needs to be longer than 6 m?
A: For pipe lengths exceeding 6 m, we can incorporate an accumulator into the hydraulic power unit to help compensate for pressure fluctuations and maintain stable thrust and operating speed. The final configuration depends on the required pipe length and operating conditions.
Hot Tags: split-type electro-hydraulic actuator, China split-type electro-hydraulic actuator manufacturers, suppliers, factory, Electro Hydraulic Actuator Aircraft, electro hydraulic actuators, Electro Hydraulic Linear Actuator, Integrated Vertical Electro hydraulic Actuator, Parallel Electro hydraulic Actuator, Split type Electro hydraulic Actuator
You Might Also Like
Send Inquiry